Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Decreasing trend of ambient dose equivalent rates over a wide area in eastern Japan until 2016 evaluated by car-borne surveys using KURAMA systems

Ando, Masaki; Mikami, Satoshi; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Saito, Kimiaki

Journal of Environmental Radioactivity, 192, p.385 - 398, 2018/12

 Times Cited Count:14 Percentile:45.76(Environmental Sciences)

Car-borne surveys using KURAMA systems have been conducted over a wide area in eastern Japan since 2011. The measurement data collected until 2016 was analyzed, and decreasing trend of the dose rates in regions within 80 km of Fukushima Dai-ichi Nuclear Power Plant were examined. The averaged dose rates tended to decrease considerably with respect to the physical decay of radiocaesium, and the ecological half-lives of the fast and slow decay components were estimated. The decrease of the dose rate in the forest was slower than its decrease in other regions, and the decrease of the dose rate in urban area was the fastest. The decrease in the dose rates obtained via the car-borne survey was larger than that obtained on flat ground with few disturbances using survey meters approximately 1.5 y after the accident; hereafter, the decrease in the dose rates obtained via the car-borne survey was same as the latter measurement.

Journal Articles

Measurement of ambient dose equivalent rates by walk survey around Fukushima Dai-ichi Nuclear Power Plant using KURAMA-II until 2016

Ando, Masaki; Yamamoto, Hideaki*; Kanno, Takashi*; Saito, Kimiaki

Journal of Environmental Radioactivity, 190-191, p.111 - 121, 2018/10

 Times Cited Count:17 Percentile:52.92(Environmental Sciences)

Ambient dose equivalent rates in various environments related to human lives were measured by walk surveys using the KURAMA-II systems from 2013 to 2016 around the Fukushima Dai-ichi Nuclear Power Plant. The dose rate of the locations where the walk survey was performed decreased to about 38% of its initial value in the 42 months, which was beyond that attributable to the physical decay. The air dose rates decreased depending on the level of the evacuation areas, and the decrease was slightly larger in populated areas where humans are active. The comparison of walk survey data with car-borne survey data indicated that the air dose rate varies largely even within a 100 m square area. The dose rates measured by the walk surveys were estimated to be medial of those along roads and those of undisturbed flat ground. The air dose rates measured by the walk surveys decreased quickly compared with the air dose rate from the flat ground measurement.

Journal Articles

CsI(Tl)/Plastic phoswich detector enhanced in low-energy $$gamma$$-ray detection

Yamasoto, Kotaro; Tsutsumi, Masahiro; Oishi, Tetsuya*; Yoshizawa, Michio; Yoshida, Makoto

Nuclear Instruments and Methods in Physics Research A, 550(3), p.609 - 615, 2005/09

 Times Cited Count:5 Percentile:41.08(Instruments & Instrumentation)

A phoswich detector composed of a thin plate CsI(Tl) scintillator and a plastic scintillator (BC-400) has been designed and evaluated to improve the sensitivity in the low-energy region of large-area plastic scintillation detector. Applicability of the CsI(Tl)/Plastic phoswich detector was examined on radioactivity measurement of massive and large-area materials. The rise-time discrimination technique was applied in order to further improve the minimum detectable activity in the low-energy region. On the basis of the estimation of minimum detectable activity, it was made clear that the energy range of large-area plastic scintillation detector can be expanded down to a few tens of keV by adding a thin plate CsI(Tl) scintillator.

3 (Records 1-3 displayed on this page)
  • 1